Appendix 1 — Default Settings Table

Default values defined in the process of the initial factory setup.

Parameter Description Default Setting Parameter Setting Object
Data Saving Type State and Calibration Analyzer
Touchstone Data Format Real-Imaginary Analyzer
Allocation of Channels Analyzer
Active Channel Number 1 Analyzer
Marker Value Identification Capacity (Stimulus) 7 digits Analyzer
Marker Value Identification Capacity (Response) 4 digits Analyzer
Marker Table OFF Analyzer
Reference Frequency Source Internal Analyzer
Trigger Signal Source Internal Analyzer
Reference Channel Error Correction ON Analyzer
System Correction ON Analyzer
Allocation of Traces Channel
Vertical Divisions 10 Channel
Channel Title Bar OFF Channel
Channel Title Empty Channel
«FAIL» Label Display (Limit Test) OFF Channel
Segment Sweep Frequency Axis Display Frequency Order Channel
Traces per Channel 1 Channel
Active Trace Number 1 Channel
Marker Coupling ON Channel
Sweep Type Linear Frequency Channel
Number of Sweep Points 201 Channel
Stimulus Start Frequency Instrument min. Channel
Stimulus Stop Frequency Instrument max. Channel
Stimulus CW Frequency Instrument min. Channel
Stimulus Start Power Level Instrument min. Channel
Stimulus Stop Power Level Instrument max. Channel
Stimulus Power Level 0 dBm Channel
Stimulus Power Slope 0 dBm Channel
Stimulus IF Bandwidth 10 kHz Channel
Sweep Measurement Delay 0 sec. Channel
Sweep Range Setting Start / Stop Channel
Number of Segments 1 Channel
Points per Segment 2 Channel
Segment Start Frequency Instrument min. Channel
Segment Stop Frequency Instrument min. Channel
Segment Sweep Power Level 0 dBm Channel
Segment Sweep IF Bandwidth 10 kHz Channel
Segment Sweep Measurement Delay 0 sec. Channel
Segment Sweep Power Level (Table Display) OFF Channel
Segment Sweep IF Bandwidth (Table Display) OFF Channel
Segment Sweep Measurement Delay (Table Display) OFF Channel
Segment Sweep Range Setting Start / Stop Channel
Averaging OFF Channel
Averaging Factor 10 Channel
Trigger Mode Continuous Channel
Table of Calibration Coefficients Empty Channel
Error Correction OFF Channel
Port Z Conversion OFF Channel
Port 1 Simulated Impedance Instrument Nominal Channel
Port 2 Simulated Impedance Instrument Nominal Channel
Port 1 De-embedding OFF Channel
Port 2 De-embedding OFF Channel
Port 1 De-embedding S-parameter File Empty Channel
Port 2 De-embedding S-parameter File Empty Channel
Port 1 Embedding OFF Channel
Port 2 Embedding OFF Channel
Port 1 Embedding User File Empty Channel
Port 2 Embedding User File Empty Channel
Measurement Parameter S11 Trace
Trace Scale 10 dB / Div. Trace
Reference Level Value 0 dB Trace
Reference Level Position 5 Div. Trace
Data Math OFF Trace
Phase Offset Trace
Electrical Delay 0 sec. Trace
S-parameter Conversion OFF Trace
S-parameter Conversion Function Z: Reflection Trace
Trace Display Format Logarithmic Magnitude (dB) Trace
Time Domain Transformation OFF Trace
Time Domain Transformation Start –10 nsec. Trace
Time Domain Transformation Stop 10 nsec. Trace
Time Domain Kaiser-Beta 6 Trace
Time Domain Transformation Type Bandpass Trace
Time Domain Gate ON Trace
Time Domain Gate Start –10 ns Trace
Time Domain Gate Stop 10 ns Trace
Time Domain Gate Type Bandpass Trace
Time Domain Gate Shape Normal Trace
Smoothing OFF Trace
Smoothing Aperture 1% Trace
Trace Display Mode Data Trace
Limit Test OFF Trace
Limit Line Display OFF Trace
Defined Limit Lines Empty Trace
Number of Markers 0 Trace
Marker Position Instrument min. Trace
Marker Search Maximum Trace
Marker Tracking OFF Trace
Marker Search Target 0 dB Trace
Marker Search Target Transition Both Trace
Marker Search Peak Polarity Positive Trace
Marker Search Peak Excursion 3 dB Trace
Bandwidth Parameter Search OFF Trace
Marker Search Bandwidth Value –3 dB Trace
Marker Search Range OFF Trace
Marker Search Start 0 Trace
Marker Search Stop 0 Trace